Articles | Volume 1, issue 1
https://doi.org/10.5194/gi-1-33-2012
https://doi.org/10.5194/gi-1-33-2012
Research article
 | 
20 Apr 2012
Research article |  | 20 Apr 2012

Design and operation of a field telescope for cosmic ray geophysical tomography

N. Lesparre, J. Marteau, Y. Déclais, D. Gibert, B. Carlus, F. Nicollin, and B. Kergosien

Related subject area

Ground-based instruments
Calculation of soil water content using dielectric-permittivity-based sensors – benefits of soil-specific calibration
Bartosz M. Zawilski, Franck Granouillac, Nicole Claverie, Baptiste Lemaire, Aurore Brut, and Tiphaine Tallec
Geosci. Instrum. Method. Data Syst., 12, 45–56, https://doi.org/10.5194/gi-12-45-2023,https://doi.org/10.5194/gi-12-45-2023, 2023
Short summary
The land–atmosphere feedback observatory: a new observational approach for characterizing land–atmosphere feedback
Florian Späth, Verena Rajtschan, Tobias K. D. Weber, Shehan Morandage, Diego Lange, Syed Saqlain Abbas, Andreas Behrendt, Joachim Ingwersen, Thilo Streck, and Volker Wulfmeyer
Geosci. Instrum. Method. Data Syst., 12, 25–44, https://doi.org/10.5194/gi-12-25-2023,https://doi.org/10.5194/gi-12-25-2023, 2023
Short summary
Design and construction of an automated and programmable resistivity meter for shallow subsurface investigation
Antenor Oliveira Cruz Júnior, Cosme Ferreira da Ponte-Neto, and André Wiermann
Geosci. Instrum. Method. Data Syst., 12, 15–23, https://doi.org/10.5194/gi-12-15-2023,https://doi.org/10.5194/gi-12-15-2023, 2023
Short summary
Feasibility of irrigation monitoring with cosmic-ray neutron sensors
Cosimo Brogi, Heye Reemt Bogena, Markus Köhli, Johan Alexander Huisman, Harrie-Jan Hendricks Franssen, and Olga Dombrowski
Geosci. Instrum. Method. Data Syst., 11, 451–469, https://doi.org/10.5194/gi-11-451-2022,https://doi.org/10.5194/gi-11-451-2022, 2022
Short summary
Design and operation of a long-term monitoring system for spectral electrical impedance tomography (sEIT)
Maximilian Weigand, Egon Zimmermann, Valentin Michels, Johan Alexander Huisman, and Andreas Kemna
Geosci. Instrum. Method. Data Syst., 11, 413–433, https://doi.org/10.5194/gi-11-413-2022,https://doi.org/10.5194/gi-11-413-2022, 2022
Short summary

Cited articles

Barrett, P., Bollinger, L. M., Cocconi, G., Eisenberg, Y., and Greisen, K.: Interpretation of cosmic-ray measurements far underground, Rev. Mod. Phys., 24, 133–178, 1952.
Bellamy, E. H., Bellettini, G., Budagov, J., Cervelli, F., Chirikov-Zorin, I., Incagli, M., Lucchesi, D., Pagliarone, C., Tokar, S., and Zetti, F.: Absolute calibration and monitoring of a spectrometric channel using a photomultiplier, Nucl. Instrum. Meth. A, 339, 468–476, https://doi.org/10.1016/0168-9002(94)90183-X, 1994.
De Asmundis, R., Avella, P., and Toglia, F.: Using RPC detectors as cosmic rays monitor, IEEE T. Nucl. Sci., 54, 670–676, https://doi.org/10.1109/TNS.2007.895505, 2007.