Articles | Volume 5, issue 2
https://doi.org/10.5194/gi-5-437-2016
https://doi.org/10.5194/gi-5-437-2016
Research article
 | 
26 Sep 2016
Research article |  | 26 Sep 2016

A coincidence detection system based on real-time software

Sindulfo Ayuso, Juan José Blanco, José Medina, Raúl Gómez-Herrero, Oscar García-Población, and Ignacio García Tejedor

Related subject area

Ground-based instruments
Calculation of soil water content using dielectric-permittivity-based sensors – benefits of soil-specific calibration
Bartosz M. Zawilski, Franck Granouillac, Nicole Claverie, Baptiste Lemaire, Aurore Brut, and Tiphaine Tallec
Geosci. Instrum. Method. Data Syst., 12, 45–56, https://doi.org/10.5194/gi-12-45-2023,https://doi.org/10.5194/gi-12-45-2023, 2023
Short summary
The land–atmosphere feedback observatory: a new observational approach for characterizing land–atmosphere feedback
Florian Späth, Verena Rajtschan, Tobias K. D. Weber, Shehan Morandage, Diego Lange, Syed Saqlain Abbas, Andreas Behrendt, Joachim Ingwersen, Thilo Streck, and Volker Wulfmeyer
Geosci. Instrum. Method. Data Syst., 12, 25–44, https://doi.org/10.5194/gi-12-25-2023,https://doi.org/10.5194/gi-12-25-2023, 2023
Short summary
Design and construction of an automated and programmable resistivity meter for shallow subsurface investigation
Antenor Oliveira Cruz Júnior, Cosme Ferreira da Ponte-Neto, and André Wiermann
Geosci. Instrum. Method. Data Syst., 12, 15–23, https://doi.org/10.5194/gi-12-15-2023,https://doi.org/10.5194/gi-12-15-2023, 2023
Short summary
Feasibility of irrigation monitoring with cosmic-ray neutron sensors
Cosimo Brogi, Heye Reemt Bogena, Markus Köhli, Johan Alexander Huisman, Harrie-Jan Hendricks Franssen, and Olga Dombrowski
Geosci. Instrum. Method. Data Syst., 11, 451–469, https://doi.org/10.5194/gi-11-451-2022,https://doi.org/10.5194/gi-11-451-2022, 2022
Short summary
Design and operation of a long-term monitoring system for spectral electrical impedance tomography (sEIT)
Maximilian Weigand, Egon Zimmermann, Valentin Michels, Johan Alexander Huisman, and Andreas Kemna
Geosci. Instrum. Method. Data Syst., 11, 413–433, https://doi.org/10.5194/gi-11-413-2022,https://doi.org/10.5194/gi-11-413-2022, 2022
Short summary

Cited articles

Blanco, J. J., Medina, J., García-Población, O., Gomez-Herrero, R., García-Tejedor, I., Ayuso, S., and Catalán, E. J.: CaLMa neutron monitor: current status, first observations and future improvements, J. Phys., 632, 012052, https://doi.org/10.1088/1742-6596/632/1/012052, 2015.
Brancaccio, F., Silva Dias, M., and Toledo, F.: Development of an analysis methodology applied to 4πβ − γ software coincidence data acquisition system, International Nuclear Atlantic Conference – INAC, 27 September–2 October 2009, Río de Janeiro, Brazil, 2009.
CANBERRA Industries: Inc. Model 8075, Analog-to-Digital Converter, Operator's manual, Canberra Industries Inc. Meriden, Connecticut, USA, November 1983.
Cecchini, S. and Spurio, M.: Atmospheric muons: experimental aspects, Geosci. Instrum. Method. Data Syst., 1, 185–196, https://doi.org/10.5194/gi-1-185-2012, 2012.
Download
Short summary
A new software coincidence method is shown which can be used to replace conventional coincidence detection with the same effectiveness. Our easy-to-build trial prototype has cost EUR 150 and replaces at least three conventional coincidence modules (over EUR 6000). This has allowed us to carry out experiments that we could not before because of the lack of resources. It detects coincidence, stores timestamp data and transfers them to a PC, allowing easier adjustments and simpler interconnections.