Articles | Volume 6, issue 2
https://doi.org/10.5194/gi-6-487-2017
https://doi.org/10.5194/gi-6-487-2017
Research article
 | 
09 Nov 2017
Research article |  | 09 Nov 2017

Merging fluxgate and induction coil data to produce low-noise geomagnetic observatory data meeting the INTERMAGNET definitive 1 s data standard

Heinz-Peter Brunke, Rudolf Widmer-Schnidrig, and Monika Korte

Related authors

Numerical evaluation of magnetic absolute measurements with arbitrarily distributed DI-fluxgate theodolite orientations
Heinz-Peter Brunke and Jürgen Matzka
Geosci. Instrum. Method. Data Syst., 7, 1–9, https://doi.org/10.5194/gi-7-1-2018,https://doi.org/10.5194/gi-7-1-2018, 2018
Short summary

Related subject area

Magnetometers
Verification and calibration of a commercial anisotropic magnetoresistive magnetometer by multivariate non-linear regression
Nicholas Belsten, Mary Knapp, Rebecca Masterson, Cadence Payne, Kristen Ammons, Frank D. Lind, and Kerri Cahoy
Geosci. Instrum. Method. Data Syst., 12, 201–213, https://doi.org/10.5194/gi-12-201-2023,https://doi.org/10.5194/gi-12-201-2023, 2023
Short summary
Quad-Mag board for CubeSat applications
Brady P. Strabel, Leonardo H. Regoli, Mark B. Moldwin, Lauro V. Ojeda, Yining Shi, Jacob D. Thoma, Isaac S. Narrett, Bret Bronner, and Matthew Pellioni
Geosci. Instrum. Method. Data Syst., 11, 375–388, https://doi.org/10.5194/gi-11-375-2022,https://doi.org/10.5194/gi-11-375-2022, 2022
Short summary
In situ calibration of the Swarm-Echo magnetometers
Robert M. Broadfoot, David M. Miles, Warren Holley, and Andrew D. Howarth
Geosci. Instrum. Method. Data Syst., 11, 323–333, https://doi.org/10.5194/gi-11-323-2022,https://doi.org/10.5194/gi-11-323-2022, 2022
Short summary
Tesseract – a high-stability, low-noise fluxgate sensor designed for constellation applications
Kenton Greene, Christian Hansen, B. Barry Narod, Richard Dvorsky, and David M. Miles
Geosci. Instrum. Method. Data Syst., 11, 307–321, https://doi.org/10.5194/gi-11-307-2022,https://doi.org/10.5194/gi-11-307-2022, 2022
Short summary
Single-event effect testing of the PNI RM3100 magnetometer for space applications
Mark B. Moldwin, Edward Wilcox, Eftyhia Zesta, and Todd M. Bonalsky
Geosci. Instrum. Method. Data Syst., 11, 219–222, https://doi.org/10.5194/gi-11-219-2022,https://doi.org/10.5194/gi-11-219-2022, 2022
Short summary

Cited articles

Brunke, H.-P., Korte, M., and Widmer-Schidrig, R.: IndCoilsFGE – A software package for merging Fluxgate and Induction Coil data V.1.0, GFZ Data Services, https://doi.org/10.5880/GFZ.2.3.2017.002, 2017.
Korepanov, V. and Rasson, J.: New INTERMAGNET fluxgate magnetometer, publications of the institute of geophysics, Pol. Acad. 75 Sc., 398–406, 2007.
Pedersen, L. W. and Merenyi, L.: The FGE Magnetometer and the INTERMAGNET 1 Second Standard, J. Ind. Geophys. Union, 30–36, 2016.
Ritter, O. and Pulz, E.: Entwicklung einer Kalibriereinrichtung für Induktionsspulenmagnetometer, Scientific Technical Report 01/10 des GeoForschungsZentrum Potsdam, https://doi.org/10.2312/GFZ.b103-0100, 2001.
Schmucker, U. and Weidelt, P.: Electromagnetic Induction in the Earth, Lectures Notes Aarhus, https://doi.org/10.1038/ncomms12883, 1975.
Download
Short summary
In magnetic observatory data, according to the INTERMAGNET definitive 1 s data standard, the fluxgate magnetometer self noise usually covers the natural signal for frequencies higher than about 30 mHz. We present a numerical method how to merge the data with induction coil data in order to drastically reduce noise and to fill the entire possible bandwidth with information on the earth magnetic field. In spectrograms we visualize interesting phenomena revealed with the method.